6
595-5770-06
TESTING
❒ Turn on the circuit breaker and light
switch.
NOTE: Sensorhasa1
1
/
2
minutewarmuppe-
riodbeforeitwilldetectmotion.When
rstturnedon,wait1
1
/
2
minutes.
❒ Switchtheon-timetoTESTpositionand
Du a l Br i t e
®
switchtotheOFFposition.
Thedetectorislesssensitivetomotiondi-
rectlytowardsitandmoresensitivetoacross
motion.
Sensor
Motion
Least Sensitive Most Sensitive
❒ Walkthroughthe coveragearea noting
whereyouarewhenthelightsturnon.
❒ If you need to change the sensitivity,
temporarilyremovethextureandmake
theadjustment.Toomuchsensitivitymay
increasefalsetriggering.
❒ SettheamountofTIMEyouwantthelight
tostayonaftermotionisdetected.(1,5,
or10minutes).
❒ Settheamountoftimeafterduskyouwant
thelightsonaccentlevel.
TEST1510MIN
ON-TIME
OFF 3 6 DUSK TO
HOUR DAWN
Avoid aiming the control at:
•Objectsthatchangetemperaturerapidly,
suchasheating vents and air condition-
ers.Theseheatsourcescouldcausefalse
triggering.
•Areaswherepets or trafficmaytrigger
thecontrol.
•Nearby large, light-colored objects
reecting light may trigger the shut-off
feature. Do not point other lights at the
sensor.
30ft.
(9.1m)
Maximum Range Maximum
Coverage Angle
6ft.
(1.8m)
180°
Motion